Unser manual and safety instructions for original Triebel Reloading dies.

Replacing components

Replacing components Fitting the spindle for the seater punch 1 Seater punch 2 Spindle 3 Counter nut with spindle 4 Counter nut 1. Screw the seater punch onto the spindle. 2. Screw the counter nut with spindle onto the spindle. 3. Screw the counter nut onto the spindle. www.triebel-guntools.de 32/37 User Manual-2.0

Troubleshooting Troubleshooting Fault Cause Result The cartridge case does not fit into the gun after sizing. The breech cannot be closed. It is possible to insert the cartridge case, but it jams. It is difficult or impossible to press the cartridge case into the die. Withdrawing the cartridge case requires a significant amount of effort. Scoring on the cartridge case, in the powder chamber, or on the case neck (inside or outside). The die does not size perfectly. The dimension from the cartridge base to the shoulder is too long. The diameter of the chamber is too small. The die does not size the diameter adequately. The chamber that the cartridge case comes from is too wide. The die is sizing too much for the wall thickness of the cartridge case. It may be OK for cartridge cases with thinner walls. Particles of the case material have fixed (cold welded) to the die or the interior sizer. Size one cartridge case without the expander and check it in the gun or in the test chamber. If it is possible to load the cartridge case, then the die sizes correctly. To ensure that the cartridge case does not contact at the case mouth, check the maximum case length. Replace the die or arrange for a specialist to set it to the correct dimension. The chamber must be inspected. Replace the die or arrange for a specialist to set it to the correct dimension. If you intend to use the cartridge cases in the same gun, then the die must be adapted by a specialist. Custom manufacturing may also be required. Size one cartridge case with an expander and one without. The difference in the diameter of the case neck should be no greater than 0.1 to 0.15 mm. For larger clearances, replace the die or arrange for a specialist to set it to the correct dimension. The particles must be professionally removed by a specialist. www.triebel-guntools.de User Manual-2.0 33/37

© Copyright 2017.Triebel Waffenwerkzeuge GmbH. Alle Rechte